AqaraUser ManualAqara

Aqara Cube T1 Pro

Sections11
Reading7 min
UpdatedApr 2026
LanguageEnglish
Section 01

Inspection and Installation

Effective distance test: Pick up the Cube and shake it or press the reset button. If the hub gives a prompt sound, it indicates that the device can communicate effectively with the hub.

* To ensure stable wireless communication, please avoid installation on metal surfaces.

02 / 11
Section 02

Mode Switching

Open the Aqara Home app, enter the device page, and click "... in the upper right corner, enter the device setting page, click "More Settings", click "Mode Switching", and select the desired mode.

03 / 11
Section 03

Battery Replacement

Open the battery cover of Cube T1 Pro with the ejector tool, take out the battery, replace it with a new CR2450 battery (note that the positive electrode of the battery is upward), and then close the battery cover again.

04 / 11
Section 04

Action mode

Flip 90° : Pick up the Cube and flip by 90° Flip 180° : Pick up the Cube and flip by 180° Rotate: Rotate the Cube on a surface Push: Push the Cube on a surface Tap: Pick up the Cube and tap it twice Shake: Pick up the Cube and shake it back and forth quickly twice

Triggered after one-minute inactivity: The Cube is moved after stands still for one minute

05 / 11
Section 05

Scene Mode

SideX up*: Flip the Cube to the X (1~6/any) side up

Pick up and hold: Pick up the cube and hold still

Shake: Pick up the Cube and shake it back and forth quickly twice

Pick up and hold: Pick up the cube and hold still

*HomeKit only supports this function.

06 / 11
Section 06

Specifications

Product Model: CTP-R01

Dimensions: 45 \times 45 \times 45 ~mm (1.77×1.77×1.77in.)

Net Weight: 76g

Battery: CR2450 (Replaceable)

Wireless Protocol: Zigbee

Operating Temperature: -10°C \sim50°C ( 14°F \sim122°F )

Operating Humidity: \leq 95% RH, no condensation

Zigbee Operation Frequency: 2405-2475MHz

Zigbee Maximum Output Power \leq 13 dBm

Online Customer Service: www.aqara.com/support

Manufacturer: Lumi United Technology Co., Ltd.

Address: Room 801-804, Building 1, Chongwen Park,

Nanshan iPark, No. 3370, Liuxian Avenue, Fuguang

Community, Taoyuan Residential District, Nanshan

District, Shenzhen, China

07 / 11
Section 07

Warnings

1. This product is not a toy, please keep children away from this product. 2. This product is designed for indoor use only. Do NOT use in humid environments or outdoors. 3. Beware of moisture, do NOT spill water or other liquids onto the product. 4. Do not place this product near a heat source. 5. Do not attempt to repair the product by yourself. All repairs should be performed by authorized personnel. 6. This product is designed only for improving the convenience of household life, and for status notifications. If the user violates the product instructions and this warning, the manufacturer is not responsible for any risks and property losses caused thereby.

Under normal use of condition, this equipment should be kept a separation distance of at least 0 mm between the antenna and the body of the user.

EU Declaration of Conformity Hereby, [Lumi United Technology Co., Ltd] declares that the radio equipment type [Cube T1 Pro,CTP-R01] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.aqara.com/DoC/

UK UK Declaration of Conformity CA Hereby, [Lumi United Technology Co., Ltd] declares that the radio equipment type [Cube T1 Pro, CTP-R01] is in compliance with Directive 2017 (SI 2017 No.1206, as amended by SI 2019 No.696). The full text of the UK declaration of conformity is available at the following internet address: http://www.aqara.com/DoC/

08 / 11
Section 08

WEEE Disposal and Recycling Information

All products bearing this symbol are waste

electrical and electronic equipment (WEEE as in

directive 2012/19/EU) which should not be mixed with

unsorted household waste. Instead, you should protect human health and the environment by handing over your waste equipment to a designated collection point for the recycling of waste electrical and electronic equipment, appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. Please contact the installer or local authorities for more information about the location as well as terms and conditions of such collection points.

Symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection

point for the recycling of electrical and electronic equipment.

09 / 11
Section 09

CAUTION

1. Risk of explosion if the battery is replaced by an incorrect type.

2. Dispose of used batteries according to the instructions. 3. Do not ingest battery, Chemical Burn Hazard. 4. This product contains a coin / button cell battery. If the coin / button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. 5. Keep new and used batteries away from children. 6. If the battery compartment does not close securely, stop using the product and keep it away from children. 7. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. 8. Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion. 9. Leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas 10. A battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas.

10 / 11
Section 10

FCC ID:2AKIT-CTP-R01

Federal Communications Commission (FCC) compliance statement:

1. This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that may cause undesired operation.

2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are

designed to provide reasonable protection against

harmful interference in a residential installation. This

equipment generates, uses and can radiate radio

frequency energy and, if not installed and used in

accordance with the instructions, may cause harmful

interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

—Reorient or relocate the receiving antenna.

—Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

—Consult the dealer or an experienced radio/TV technician for help.

The SAR limit of FCC is 1.6W / kg over 1 gram of tissue for use against the body. The highest SAR value reported under this standard during product certification when properly worn on the body is 0.17W / kg . This device was tested for typical body-worn operations with the edge of the device kept 0mm from the body.

IC:22635-CTPR01

11 / 11
Section 11

IC NOTICE TO CANADIAN USERS

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:

(1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.

This Class B digital apparatus complies with Canadian ICES - 003.

This device complies with RSS - 247 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference.

The SAR limit of IC is 1.6W/kg over 1 gram of tissue for use against the body. The highest SAR value reported under this standard during product certification when properly worn on the body is 0.17W/kg, This device was

tested for typical body-worn operations with the edge of the device kept 0mm from the body.

Scan to get the Zigbee Install Code on the last page of the manual.

*Please read this manual carefully and keep it in a safe place. *If necessary, the contents of this manual will be modified or adjusted without special notice.

Assistance
Stuck on a step?
Ask Pindear — grounded answers drawn from this manual and Aqara’s documentation.
Colophon
Sourced from Aqara’s official documentation and typeset for web reading by Pindear. Always refer to the official source for critical safety information.
Back to Aqara Cube T1 Pro